SyncTwinTECHNOLOGIES
Platform

The line runs on your network

Units, their programs and the links between them live on the box in your shop. The cloud is for design, configuration release and updates.

Platform diagram: site, cloud, browser On the customer's site — the controller, drives and simulator; in the cloud — program development and tests on a bench with drives; the browser is linked to both sides. Your site controllerdrives on EtherCATsimulatorline data Cloud PLC programsmotions and linestests on the benchwith drives Browser — a window
Local network

The line runs on your network

  • Units on the box in your shopThe box (Ryzen 7 PRO, real-time OS) hosts virtual real-time controllers. It runs the unit programs (IEC 61131-3, SFC, PackML), the message bus and the simulator for commissioning; units talk to each other locally.
  • No inbound portsThe box connects to the cloud only through an outbound secure connection. No public IP or port forwarding is needed.
  • Signals straight from the boxAn engineer on the same network sees line signals straight from the box, without the cloud. Access requires a signed token issued after sign-in; an outsider on the plant network gets nothing.
  • Cloud: design and releaseDigital twin, programs, unit debugging in the browser, configuration release and updates.
What it consists of

One copy of the unit — from screen to servo drive

Twin

The simulator is built from it and the controller configuration is printed from it.

Programs

Logic in IEC 61131-3, cutting and motion programs.

Simulator

Product, conveyor, sensors — through the same input as on site.

Screen

Run in the browser; next to the real line, its shadow in the simulator.

What sets it apart

The whole vertical

  • One copy, not twoThe model for verification and the controller configuration come from one twin.
  • Browser → twin → controller → servoThe whole path of the program — in one platform.
  • Open standardsIEC 61131-3, ISA-88/PackML, AutomationML, EtherCAT, CiA 402.
  • Cloud or your perimeterThe platform also runs on your servers.
Status

What works and what is worked out in the implementation

CapabilityStatus
Unit test run in the browserworks
Simulator next to the controller, sensors through the same inputsubject of the implementation
Line shadow on real drivessubject of the implementation
Virtual units started by a neighbour's sensorsubject of the implementation
Where things run

Site, cloud and browser

PlaceWhat runsWhat follows from it
SiteThe box is a computer next to the equipment: isolated virtual machines with a real-time loop and their own EtherCAT port; drives, I/O, machine-side panelReal time is computed next to the hardware; the machine is controlled even without an external network. Box facts — “Box and requirements”
CloudProgram development, compiler, runs on virtual axes, remote tests on a test bench with drivesPrograms are written and checked without a trip to site
BrowserTwin, program labs, drive commissioning, unit test runA window both ways: to the site and to the cloud

What crosses the cloud boundary is intent — the program and the “run” and “stop” commands. Jog and raw drive commands stay at the equipment.

Principle

The twin is the single source of truth

The configuration is generated

Axes and limits, drives, tooling, tools, zeros — in the twin. The control configuration is not written by hand: change a field and the next start goes to the test bench with it.

An edit on the test bench is a second truth

A file edited by hand on the test bench itself disappears at the next start. That is why edits are made in the twin, where everyone sees them.

A number has an origin

Datasheet and measured numbers are stored with their source. The platform does not pass a datasheet value off as a measurement: “from the datasheet, not verified by touch” is a normal field state.

Mechanism and instance

A mechanism is a reference body model: links, joints, limits. An instance is your machine: its axes are bound to profiles, it carries tooling, it has a place.

Two modes of one twin

Virtual axes — drives stand still, blocks pass. Drives — commands go over the bus. The mode is chosen explicitly; the platform never switches to “drives” silently.

A green run is not proof

An axis with no assigned drive moves in simulation just like a real one. The screen states this on a separate line.

Next step

Discuss an implementation

Describe the unit or line — we will tell you what we will verify and in what time. Target indicators are fixed in the implementation specification.

Request access

Implementation →