SyncTwinTECHNOLOGIES
On-premise installation

Controller and simulator — on your site

The platform is installed inside the enterprise perimeter: a server, a box next to the equipment, virtual machines for units. Line data stays with you.

On-premise installation diagram Enterprise server, below it the box — a computer next to the equipment with isolated virtual machines; each machine has its own real-time loop and its own EtherCAT port to which drives and I/O are connected. Enterprise server The box is a computer next to the equipment unit machine 1real timeown EtherCAT port unit machine 2real timeown EtherCAT port drives, I/O drives, I/O
How it is built

A unit runs next to its equipment

  • The box is a computer next to the equipmentIt hosts isolated virtual machines with a real-time loop; on the bench it is a mini PC, specs below.
  • Each machine has its own EtherCAT portA unit drives its own bus: the drives and I/O of its area.
  • Configuration — from the twinThe controller receives it at every start; an edit on site does not create a second truth.
  • Virtual axes or drives — by explicit choiceOne twin is brought up without hardware or on drives; the mode is visible on screen.
  • The machine panel works without the cloudStart, stop and commissioning — on site.

Updates without internet and diagnostics without remote login are built into the installation design and are worked out in the implementation. What is known about the box is in the “Box and requirements” section; box installation instructions are available on request.

Box and requirements

What is known about the box — from the live bench box

WhatFact
Bench boxMini PC: AMD Ryzen 7 PRO 6850H processor (8 cores / 16 threads), 12 GB of memory available to the system
Operating systemReal-time OS
InstallerDesigned for a real-time OS with hardware virtualization
Control machines4 virtual machines run at once on the live box: each is its own control machine — a machine tool or a unit with EtherCAT drives, or virtual axes
EtherCAT portA machine with real drives gets its own physical network port, passed through into the virtual machine (PCI passthrough); cores for real time are pinned
SetupOne installer command with a binding code from your personal section of the platform; the box identity is kept on reinstall
Without the cloudThe box works without the cloud: control stays on site; the cloud is for remote development and tests
Developer workstationThere are installers that need no administrator rights — for a developer workstation, not for drive control
WhatStatus
Enterprise server for several boxesas agreed during the implementation
Minimum box requirementsas agreed during the implementation
More than four machines per boxas agreed during the implementation
Certificationsas agreed during the implementation

Specs were taken from the live bench box on 09.10. This is the test laboratory box, not a requirement for your hardware.

What it consists of

Server, box, virtual machine, test bench

WhatWhat it isWhat it is not
Enterprise serverThe platform inside your perimeter: twins, programs, line projects, browser access within your networkNot where real time is computed
BoxA computer next to the equipment; real time is computed on itNot a server and not the cloud
Automation unitsSeveral automation nodes run from one box, split across EtherCAT bus segmentsEach bus segment has its own EtherCAT port on the box
Test benchWhat the platform sees on the other side: a box machine with its own busMany machines are bound to a test bench, but only the one brought up is current
Axis profileThe drive’s role on the test bench: servo parameters, sign, backlash, zero, speed ceilingNot created automatically: no profile — the start is refused in words
Without an external network

What runs on site on its own

Unit cycle

The package on the box is self-contained: the description of axes and channels, the loop profile and the current program are already there. The cloud receives facts but the cycle does not need it.

Machine panel

The local web panel on the box shows state and coordinates with the same channel names as everywhere else.

Drive commissioning

Jog, measurements, parameters — at the equipment. Parameters are written to the drive’s RAM, to its permanent memory — only with a separate button.

  1. ServerThe platform is installed inside your perimeter.
  2. BoxOne installer command with a binding code; unit machines.
  3. BusScan: drives and I/O of the area.
  4. ProfilesBus device → profile → axis.
  5. PurposeMachines and units are assigned to the test bench and brought up from the twin.

The first installation at a customer is in the implementation. The enterprise server, minimum box requirements and installation scope — as agreed during the implementation.

Next step

Discuss an implementation

Describe the unit or line — we will tell you what we will verify and in what time. Target indicators are fixed in the implementation specification.

Request access

Implementation →

Request access