SyncTwinTECHNOLOGIES
For whom · plants

The line is verified before start-up — data stays with you

Your line’s program runs on the twin before the equipment arrives. Control, drives and data are on your site.

What the plant gets

Start-up without surprises on site

  • The program is verified before the equipment arrivesOn site only binding sensors and axes remains.
  • The equipment is yoursWe work on your equipment or on what you choose from your supplier.
  • Data — inside your perimeterThe platform is installed on your servers; the panel at the machine works without the cloud.
  • The commissioning engineer edits the logic on their ownIEC 61131-3 and open drive profiles.
  • Line shadow next to the real lineThe same commands go to the simulator; differences are visible at once.
Implementation

An R&D stage with a result on paper

  1. SpecificationTarget figures and scope of results.
  2. WorkLine twin, experimental control configuration.
  3. TestsR&D report and test protocol on your equipment.

Support measures and tax accounting of R&D — in the section questions and answers.

What changes

Line start-up — before and after the twin

StageWithout a twinWith a twin
Before purchaseA decision by catalogue and placementThe line in 3D and the calculated pace in the R&D report
Before the equipment arrivesThe logic waits for hardwareThe program is verified by the compiler, the lab and a run
On siteDebugging logic at the machineBinding sensors and axes
After start-upThe model is thrown awayLine shadow: axis facts and divergences — a subject of the implementation

After start-up the model keeps working

Line shadow: the same commands go both to the equipment and to the model in the simulator; the “model expected — sensor silent” mismatch is visible on screen.

A new unit — virtually first

Its cycle starts on the neighbour’s real sensor; the real unit later takes its place without rebuilding the line.

The same commands — to equipment and model

Feedback comes from both sides and is compared; control stays with your staff. This mode is a subject of the implementation.

What stays with you

Equipment, data and knowledge — yours

Equipment

You do not need to buy it from us: we work on your equipment or on what you choose from your supplier or integrator.

Data

The line model opens in the browser inside your network; the deployment scheme for your security requirements is agreed in the specification.

Knowledge

Logic — in IEC 61131-3, drives — on open profiles: a commissioning engineer familiar with them finds their way alone. Handing results over to the team is part of the stage.

Support and accounting

The implementation as R&D

Support measures

Support measures exist for deployments — the Skolkovo Foundation, the Foundation for Assistance to Innovation, the Industrial Development Fund. Availability depends on the competition terms.

Tax accounting

R&D expenses from the Government list can be accounted for in profit tax with an increasing coefficient; check applicability with a tax adviser.

Safety

The cell safety circuit is a separate hardware circuit; torque to drives — only inside a motion step. Security and data →

Sources and terms — in the section questions and answers.

Questions

Plant questions

What if the target indicators are not reached?

The achieved figures and the reasons for divergence are recorded in the R&D report and the test protocol. This is the basis for a decision: refine, change the approach or stop.

Is training needed?

The logic is written to IEC 61131-3 and drives work on open profiles, so a commissioning engineer familiar with them finds their way alone. The line model opens in the browser; the panel at the machine gives start, stop and state.

Can we start small?

Yes: the implementation starts with three line cells, payment in stages by acts — the first act is the model and cell layout on screen.

Do you work with our WMS/MES and warehouse platforms?

Yes. It works alongside your WMS/MES and warehouse platforms — we are responsible for the equipment level. The scope of data exchange is fixed in the implementation specification.

Next step

Discuss an implementation

Describe the unit or line — we will tell you what we will verify and in what time. Target indicators are fixed in the implementation specification.

Request access

Implementation →

Request access